| D12 Data (linear setting with subsonic filter) |
 |
| Rated output power (THD+N < 0.1%) |
2 x 750 W into 8 Ω, both channels are driven |
| |
2 x 1200 W into 4 Ω, both channels are driven |
 |
| S/N ratio (unweighted, RMS) |
> 110 dBr |
 |
| |
| D12 Connectors |
 |
| INPUT/LINK ANALOG A/B |
3 pin XLR female/male |
 |
| INPUT/LINK DIGITAL AES/EBU |
3 pin XLR female/male |
 |
| Sampling rate |
48 kHz / 96 kHz |
 |
| OUT CHANNEL A/B |
Optional EP5/NL4/NL8 |
 |
| REMOTE |
2 x RJ 45 parallel |
 |
| SERVICE |
SUB-D9 female |
 |
| |
| D12 Digital Signal Processing |
 |
| Sampling rate |
96 kHz / 27 Bit ADC / 24 Bit DAC |
 |
| Basic delay / latency analog input |
0.3 ms |
 |
| |
| D12 Power supply |
 |
| Autosensing switch mode power supply for |
115/230V, 50 - 60 Hz |
| |
optional 100/200V, 50 - 60 Hz |
 |
| Mains connector |
PowerCon®  |
 |
| |
| D12 Remote network |
 |
| Remote network |
CAN-Bus |
 |
| |
| D12 Dimensions, weight |
 |
| Height x width x depth |
3 RU x 19" x 353 mm / 13.9" |
 |
| Weight |
13 kg / 29 lb |
 |
 |
PowerCon® is a registered trademark of the
Neutrik AG, Liechtenstein |
 |
|
We reserve the right to make
any necessary changes to the products and the published specification. As part of our
ongoing product development program we try, where possible, to maintain the highest
degree of product compatibility.
|