P1200A Mainframe

The P1200A mainframe is housed in a 3 rack unit high, 19" rack mount enclosure. The mainframe incorporates power supplies for the controllers and mainframe electronics, two power amplifiers, softstart, monitoring and protection circuits with the associated indicators and all connectors. All functions can be remotely interrogated and altered via the d&b Remote Interface Bridge (RIB). Used with d&b C or E-Series loudspeakers, the mainframe can be fitted with either one loudspeaker controller module plus the mono option, or two loudspeaker controller modules. The two channel power amplifier in the P1200A mainframe is a low feedback, low distortion design, fully protected from damage by overheating or connection to faulty or inappropriate loads, and it exhibits good stability into reactive loads along with excellent handling of fast rise-time signals and signal overload conditions. The P1200A is also available as a dual voltage (115 V / 230 V) autosensing version.

Data

Data

Mainframe with two power amplifiers, each rated 600 W into 4 Ohms, fitted with appropriate controllers1

Dimensions mm (H x W x D) 3 RU x 19" x 353
Weight kg 22
Dimensions inch (H x W x D) 3 RU x19x 13.9
Weight lb 48.5
  1. maximum output power, THD + N < 0,1%

Documentation

Documentation

Title Language Date Size
Manual P1200A, C & E-Series, complete English 09.12.2002 3 MB
TI-212 Basic remote for A1/P1200A/E-PAC English 26.08.1999 231 KB